OPERATION

The Annugas Production Enhancer® is an engineered piece of equipment. Only Annugas Compression Consulting Ltd. Service Technicians are trained and qualified to service our equipment.

Modifying parts and not using proper nuts, bolts and washers will void your warranty and may cause personal injury.

Max. working pressure at 0 psig suction:
AG648 & AG636 – 0-400 psi

AG848 & AG836 – 0-225 psi

AG1048 & AG1036 – 0-135 psi

A regulator can be used to prevent casing from going into a vacuum or to prevent excessive rod load, which can cause damages to pumpjack, compressor or both.

DO DON’T
When pumping unit is shut down the piston rod should be inside compressor.
During winter months, methanol can be used to prevent freezing.
WD40 has been put into suction line to free piston rings. Follow next 4 steps:

Step 1 - shut pumping unit down with compressor piston on bottom.

Step 2 - shut off valves and decompress compressor.

Step 3 - take suction hose off at compressor and pour 1-2 litres in it and put hose back on.

Step 4 - open suction valve and blow WD-40 into compressor and don't start unit for 1-2 hrs.

Gauges should be put on suction and discharge to make sure compressor is working properly.

The compressor should be maintained by an Annugas Service Technician on an annual basis, cleaned inside and parts replaced if needed.

Don't leave suction valve open when pumping unit is shut down. It will become a scrubber if casing pressure builds up enough to flow gas through it. When it is started up mounting bolts may break or the piston can be pulled off. If needed a scrubber can be installed at suction inlet.

Don't lengthen stroke of pumping unit, increase pressure relief valve setting, or modify base without first calling Annugas Compression Consulting Ltd. 1-866-ANNUGAS (266-8427).

Don't oil or grease bearings, use steamer on compressor, heat trace or insulate cylinder.
Don't remove compressor from pumping unit by taking cross pins out of bearing and clevis, top or bottom.

If the compressor is not needed in the field, it should be examined by an ANNUGAS SERVICE TECHNICIAN, cleaned inside and stored in a dry place.

ANNUGAS PRODUCTION ENHANCER® - ENGINEERED DESIGN

The ANNUGAS PRODUCTION ENHANCER® meets the design intent of API 618 "Reciprocating Compress".

The pressure components in the equipment meet or exceed ASME section V111 "Boiler And Pressure Vessel Code" requirements.

Materials are in accordance with the requirements of NACE MRO175.

No welding is done to heads, cylinder, top and bottom clevis or bearing swivel housings.

Engineered design has been reviewed and certified by:

Ball Associates Engineering Ltd.
Dr. Bruce E. Ball, P. Eng.

"The compressor assembly was designed on the intent indicated in API 618, and exceeds the requirements for ASME VIII, Division 1 for minimum head and shell thickness requirements at the pressure ratings stipulated by the manufacturer. The pressure limitations are determined by the mechanical performance rather than the pressure retention capability of the vessel. As a safety feature, the mounting bolts are the structural limiting feature of the compressor. The materials of construction are proprietary, but are in accordance with the requirements of NACE MR0175.

The compressor is designed to be driven by the walking beam of a pump jack. The location of installation needs to be calculated when the pump is near the pump jack manufacturer's capacity to ensure that components of the pump are not overstressed due to gas compressor installation.

There is no limitation on the operating speed of the compressor due to the compressor design. Speed limitations are based on the ratio of water to gas in the casing annulus and the downstream capacity." - Dr. Bruce E. Ball, c/o Ball Associates Engineering Ltd

Sizing Formula

By using the formula below, you can arrive at the pressure (PSIA) that an Annugas Production Enhancer® will draw the casing pressure down to.

Formula: MCF/D x 1600

S X L X A
= PSIA

MCF/D is the gas production of the well.

Where:

S = Strokes/minute of walking beam
L = Length of stroke of Annugas in feet
A = Area of Annugas piston in square inches
P = Suction pressure absolute (PSIA)

And:

Diam. of Piston (in.)

Square Inches

6
8
10

51.5
95.5
152.0

Example:

(Model AG648)
S=6, L=4, A=51.5
12MCF/D

12 X 1600

6 x 4 x 51.5
= 15.5 PSIA

Subtract absolute pressure (14) to get guage reading

     